Position:Home > Product > Oil Filter Machine > Pall >

replacement for PALL HNP vacuum oil purifier

Release date:2012-11-03 Author:LEFILTER



HNP vacuum oil purifier


Brief introduction
HNP series oil purifier is desined to filtering oil by remove water,air and dirty. Oil oxidation,Lubrication performance loss and aeration influence directly on reliability 
of system and service life of system component and oil.

The Pall HNP fluid conditioning purifier removes 100% of free water and as much as 80% of dissolved water. It also removes 100% of free and entrained gases and 
up to 80% of dissolved gases. Particulate removal is achieved using a high beta rated Ultipor® III filter element to polish the fluid before discharge back to the system
 reservoir.Other replacement filter media grades are also available to suit application requirements.

The HNP can be moved from one system to another or left as a permanent installation. The HNP purifier is simply connected to an electric supply, the inlet valve 
opened and “reset” and “start” buttons pressed to start the fluid purifying process.
Automatic controls, integral to the unit, constantly monitor the operation and will safely shut down the system if fluid levels and pressures are outside normal limits.

Safety features include high and low level float level switches, discharge relief valve (set at 100 psid/7 bar), inlet oil vacuum pressure switch and drip tray float switch.

The HNP fluid conditioning purifier has been designed to be robust and reliable under the most arduous of conditions. All components are easy to maintain and filter 
elements are readily accessible for change out.

Technical data

Model HNP006 HNP021 HNP073 HNP200
 Flow rate (L/min) 10 20 70 229
Inlet pressure(bar) 10 -0.4~0.4 -0.4~3 -0.4~3
Outlet Max pressure(bar) 10 7 7 8
Normal work  vacuum(bar) -0.6~-0.9
Inlet size G1 1/4'' G1'' G2'' G4''
Outlet size G1'' G1'' G1 1/2'' G3''
Motor power(KW) 0.67 2.25 6.4 22.7
Oil type Hydraulic oil,lube oil,turbine oil
Peak viscosity(cSt) 700
Temperature Range(℃ ) 10~70
Net Weight(Kg) 75 180 450
(600 with heater)
1760

Size
L(mm) 695 1090 1580 2679
  W(mm) 455 620 680
(1170 with heater)
1662
  H(mm) 1041 Movable 1040 1880 (2113
With heater)
3266
      Fixed 1020 1780    
Dehydration Free water Remove 100% 
  Dissolved water Remove90%  Remove 80% Remove 90%
Deaeration Free gas Remove 100% 
  Dissolved gas Remove 80%